# Ears with Erica > Praxis Audiology (ETS 5343) prep for audiology graduate students, with study help in every year of the Doctor of Audiology (Au.D.). Ears with Erica was created by Erica Guberman, Au.D., an audiologist who started @earswitherica on Instagram in graduate school. The main focus is Praxis Audiology prep. StudyHub also covers coursework across every year of the AuD, from anatomy, hearing science and phonetics onward. What it offers: - Praxis prep: full-length Praxis-style practice exams (120 questions, two hours, scored by content category) and a free sample of eight Praxis Audiology practice questions with explanations on the Praxis page. - StudyHub: an interactive study library with over a thousand practice questions and a reason for every answer choice, worksheets and flashcards, drills (masking, audiogram plotting, diagnostic trees, sequencing) and branching clinical cases. - Study sessions with Erica: one-on-one or small-group, over Google Meet, for coursework and Praxis prep. Sessions are educational and do not include clinical supervision, clinical advice or hours toward certification. - Free live Kahoot sessions on audiology topics. Dates are posted on the Live page and on Instagram. Prices (USD, November 2026; the Membership page is the live source if these differ): - Core: $35/month or $360/year. Includes one full-length practice exam. - Premium: $55/month or $570/year. Includes all three full-length practice exams. - Praxis Prep Pass: $150 for 90 days of everything in Premium. One payment, does not renew. - Study sessions: $80 for 60 minutes, $150 for 120 minutes, or $25 for a group hour with up to 10 students. Contact: hello@earswitherica.com. Instagram: https://www.instagram.com/earswitherica The Praxis exam is owned by ETS (Educational Testing Service). Ears with Erica is not affiliated with, endorsed by, or sponsored by ETS. ## Pages - [Praxis Practice Test](https://www.earswitherica.com/praxis): Praxis Audiology (5343) prep, eight free practice questions with explanations, full-length practice exams, and the $150 / 90-day pass. - [Audiology Praxis Study Guide](https://www.earswitherica.com/audiology-praxis): 5343 study guide with ETS content categories, a topic map and study timelines. - [StudyHub](https://www.earswitherica.com/studyhub): Interactive audiology study tools for every year of the AuD, through the Praxis. Plans start at $35/month. - [Membership](https://www.earswitherica.com/membership): Core, Premium and the Praxis Prep Pass, with current prices. - [Study Sessions](https://www.earswitherica.com/tutoring): One-on-one and small-group study sessions with Erica Guberman, Au.D., over Google Meet. $80 for 60 minutes, $150 for 120 minutes, $25 for a group hour. - [FAQ](https://www.earswitherica.com/faq): Who it's for, what it covers, and how membership and live Kahoots work. - [Live Kahoots](https://www.earswitherica.com/live): Free live Kahoot sessions. - [About](https://www.earswitherica.com/about): Erica Guberman, Au.D., and why Ears with Erica exists. - [Home](https://www.earswitherica.com/) - [Learn](https://www.earswitherica.com/learn): Short public explainers, one audiology question per page. ## Optional - [Privacy Policy](https://www.earswitherica.com/privacy) - [Terms of Service](https://www.earswitherica.com/terms) ## Learn - [ABR waves I, III, and V: latencies and what shifts them](https://www.earswitherica.com/learn/abr-waves-i-iii-v): At a high click level, normal adult latencies are roughly wave I at 1.6 to 1.65 ms, wave III at 3.7 to 3.8 ms, and wave V at 5.5 to 5.65 ms, with an I to V interpeak interval near 4 ms. - [Acoustic reflex thresholds and the four-box patterns](https://www.earswitherica.com/learn/acoustic-reflex-thresholds-and-patterns): Normal contralateral acoustic reflex thresholds run roughly 75 to 95 dB HL at 500 to 2000 Hz, about 2 to 5 dB lower for ipsilateral, and broadband noise thresholds sit about 20 dB lower than tonal ones. - [Adult cochlear implant candidacy criteria](https://www.earswitherica.com/learn/cochlear-implant-candidacy): Adult cochlear implant candidacy generally requires moderate to profound sensorineural hearing loss and limited benefit from well-fitted hearing aids, most often shown as poor sentence or word recognition in the best-aided condition. - [Audiology Praxis practice questions with rationales](https://www.earswitherica.com/learn/audiology-praxis-practice-questions): Five questions from the Ears with Erica bank, one from each of the five domains ETS publishes for the Praxis Audiology exam, each shown with a rationale for every option and a short teaching point. - [Auditory processing disorder testing](https://www.earswitherica.com/learn/auditory-processing-disorder-testing): Auditory processing testing asks whether listening trouble remains after the audiogram is explained. - [Dix-Hallpike BPPV test: findings by canal](https://www.earswitherica.com/learn/dix-hallpike-bppv-canals): Dix-Hallpike BPPV by canal: posterior upbeating torsional nystagmus to the affected ear, fading in a minute. - [Head and neck anatomy for audiology: ear and cranial nerves](https://www.earswitherica.com/learn/head-and-neck-anatomy-for-audiology): The outer ear collects sound, the middle ear matches it to inner-ear fluid, and the inner ear splits hearing from balance. - [How to read an audiogram: symbols, degree, and PTA](https://www.earswitherica.com/learn/reading-an-audiogram): Circles and X's mark unmasked air conduction, carets mark bone conduction, and triangles and squares mark masked air conduction, in red for the right ear and blue for the left. - [Interaural attenuation values for clinical masking](https://www.earswitherica.com/learn/interaural-attenuation-masking): Use the minimum of the reported range so cross-hearing is never missed: 40 dB for supra-aural earphones, 55 dB for insert earphones, and 0 dB for bone conduction. - [IPA phonetics basics for speech audiometry](https://www.earswitherica.com/learn/ipa-phonetics-basics): General American vowels differ by height, backness, and rounding, and a few of them glide. - [Newborn hearing screening and the JCIH timeline](https://www.earswitherica.com/learn/newborn-hearing-screening-timeline): The Joint Committee on Infant Hearing's 1-3-6 timeline calls for screening by 1 month, diagnostic evaluation by 3 months for anyone who does not pass, and enrollment in early intervention by 6 months for anyone diagnosed with hearing loss. - [NIOSH vs OSHA noise exposure limits](https://www.earswitherica.com/learn/osha-noise-exposure-limits): NIOSH vs OSHA: OSHA PEL 90 dBA 8-hour TWA, 85 dBA action level, 5 dB exchange. - [Open set vs closed set speech testing: what changes and why](https://www.earswitherica.com/learn/open-set-vs-closed-set-speech-testing): Open set testing asks a listener to repeat a word or sentence with no choices given, so a correct response reflects genuine recognition. - [PB max, PI-PB functions and rollover explained](https://www.earswitherica.com/learn/pb-max-and-rollover): PB max is the highest word recognition score an ear produces, found by testing at more than one presentation level rather than reading off a single score. - [Pediatric audiology: which test at which age](https://www.earswitherica.com/learn/pediatric-audiology-test-battery-by-age): Pediatric behavioral testing follows a developmental progression: behavioral observation audiometry for infants under about 6 months, visual reinforcement audiometry from roughly 6 months to 2 years, conditioned play audiometry from about 2 to 5 years, and conventional audiometry from about 4 or 5 years on. - [Praxis Audiology exam format and how to prep](https://www.earswitherica.com/learn/praxis-audiology-exam-format): 5343 exam format: 120 questions, two hours, 162 passing score, five ETS domains (assessment weighted most). - [Psychoacoustics basics: threshold, loudness, and masking](https://www.earswitherica.com/learn/psychoacoustics-basics): A threshold is the softest sound you still detect, and 0 dB HL is the average normal threshold, not silence. - [REM verification: real-ear measurement and targets](https://www.earswitherica.com/learn/real-ear-measurement-verification): REM verification confirms hearing-aid output at the eardrum for soft to loud speech. - [Speech science basics: source, filter, and the speech banana](https://www.earswitherica.com/learn/speech-science-basics): The vocal tract filters a source. - [SRT vs WRS: speech reception and word recognition](https://www.earswitherica.com/learn/srt-vs-word-recognition-testing): SRT vs WRS: SRT is 50 percent spondee ID and should match PTA within 5 to 10 dB. - [Tympanogram types A, As, Ad, B, and C explained](https://www.earswitherica.com/learn/tympanogram-types-explained): Tympanogram types: A normal peak; As shallow (stiff/otosclerosis); Ad tall (discontinuity); B flat; C negative-pressure peak (eustachian tube dysfunction). - [Vestibular testing beyond BPPV: how the battery fits](https://www.earswitherica.com/learn/vestibular-testing-beyond-bppv): BPPV is a positioning question. - [W-22 vs PBK-50: choosing a word recognition list](https://www.earswitherica.com/learn/w-22-vs-pbk-50-word-lists): The CID W-22 lists are open set monosyllabic word recognition lists built for adults, phonetically balanced and scored as percent correct out of 50 words.