Audiology Praxis practice questions with rationales
Where can I practice real Praxis Audiology-style questions with a full rationale for every option?
Written by Erica Guberman, Au.D. · Updated November 10, 2026
Five questions from the Ears with Erica bank, one from each of the five domains ETS publishes for the Praxis Audiology exam, each shown with a rationale for every option and a short teaching point. Reading why the wrong answers are wrong, not only which option is correct, is the habit that actually transfers to a new question on exam day.
How to use this page
Work each question below before you read the explanation. Pick an answer, then read the rationale for every option, not just the correct one. Wrong options are often built around a common mix-up, and it helps to see why they are wrong.
This page has five worked examples, one from each domain. For eight more, try the short free sample on the Praxis Prep page. The Praxis Prep Pass is on that page too.
How the exam's domains are weighted
ETS organizes the Praxis Audiology exam into five domains and publishes their approximate weights: Foundations about 24 questions (20 percent), Prevention and Screening about 12 (10 percent), Assessment about 42 (35 percent), Intervention about 30 (25 percent), and Professional and Ethical Responsibilities about 12 (10 percent). The five questions below follow that order, one per domain, and the assessment item is the kind worth the most practice, since that domain alone is more than a third of the exam. Beginning January 11, 2027, ASHA's exam moves from ETS to PSI and is renamed the National Audiology Examination; ASHA states that the questions, content areas, structure and passing standard do not change.
The full topic map, an 8-week and 4-week study timeline, and a longer set of study tips live on the Audiology Praxis study guide; this page is the worked-example half of that guide.
Reading a rationale
Each question below has a stem, a set of options, and a short teaching point after the options. Exactly one option is marked correct, and every option, right or wrong, carries its own explanation of why it is or is not the answer. Reading a wrong option's rationale usually surfaces the specific fact or calculation step being tested, which is often more useful for study than the correct answer's rationale alone, since it names the mistake the question is designed to catch.
Try a question from the bank
Same format as the exam: options with a reason given for every one of them, from the real Ears with Erica question bank. More like it live in StudyHub.
Sample item from the bank
Taking the speed of sound in air as approximately 344 m/s, what is the wavelength of a 1000 Hz pure tone?
- 0.034 mIncorrectThis is the wavelength of a 10,000 Hz tone. A decimal place was lost in the division.
- 2.9 mIncorrectThis is frequency divided by speed (1000/344), which inverts the formula. Wavelength is speed divided by frequency.
- 3.44 mIncorrectA 100 Hz tone has this wavelength. Check the exponent on the frequency.
- 0.344 mCorrectWavelength = speed / frequency = 344 / 1000 = 0.344 m, about 34 cm.
What to take from it
Wavelength and frequency are inversely related, so low frequencies have long wavelengths that diffract around obstacles the size of a head. That single fact drives duplex theory and much of room acoustics.
Sample item from the bank
Which pairing of noise exposure criterion and exchange rate is correct?
- OSHA PEL 85 dBA, 3 dB exchange; NIOSH REL 90 dBA, 5 dB exchangeIncorrectThe values are swapped between agencies. NIOSH is the more protective of the two, recommending 85 dBA with a 3 dB exchange rate, while OSHA is the enforceable but more permissive standard at 90 dBA with a 5 dB exchange rate.
- OSHA PEL 90 dBA, 5 dB exchange; NIOSH REL 85 dBA, 3 dB exchangeCorrectOSHA sets an enforceable 8-hour TWA permissible exposure limit of 90 dBA using a 5 dB exchange rate. NIOSH recommends an 8-hour TWA recommended exposure limit of 85 dBA using the 3 dB equal-energy exchange rate.
- Both OSHA and NIOSH use 85 dBA, 3 dB exchangeIncorrect85 dBA is OSHA's action level, which triggers a hearing conservation program, not its permissible exposure limit. OSHA retains the 5 dB exchange rate, and only NIOSH uses 85 dBA with a 3 dB exchange rate.
- OSHA PEL 90 dBA, 3 dB exchange; NIOSH REL 85 dBA, 5 dB exchangeIncorrectThe exchange rates are swapped between agencies. The 3 dB rate is the equal-energy rule NIOSH endorses; the 5 dB rate is OSHA's, which credits intermittency.
What to take from it
The exchange rate is how much the level may rise for each halving of duration. Under OSHA's 5 dB rate, 95 dBA is allowed for 4 hours; under the NIOSH 3 dB rate, 88 dBA is allowed for 4 hours. NIOSH also caps exposure at 140 dB peak SPL for impulse noise.
Sample item from the bank
A patient's left-ear SRT is 55 dB HL, MCL 80 dB HL and UCL 95 dB HL. What is the dynamic range for speech, and what does it suggest?
- 40 dB, which is markedly reducedCorrectDynamic range for speech is conventionally UCL minus SRT, or 95 minus 55. Normal listeners have roughly 90 to 100 dB, so 40 dB is severely compressed, calling for compression rather than linear gain. It is consistent with loudness recruitment, and linear amplification would quickly exceed the UCL.
- 15 dB, the interval between MCL and UCLIncorrectThat interval describes headroom above comfort and is useful for setting output limits, but the dynamic range for speech is measured from threshold to UCL.
- 40 dB, a normal dynamic range requiring no special considerationIncorrectThe arithmetic is correct but the interpretation is not. Normal dynamic range is roughly 90 to 100 dB, so 40 dB is compressed to less than half of normal.
- 25 dB, the interval between SRT and MCLIncorrectThe interval from threshold to comfort helps in selecting presentation levels, but it is not the dynamic range.
What to take from it
A narrow dynamic range is the behavioral signature of loudness recruitment from outer hair cell loss, and it drives the choice of wide dynamic range compression with a low kneepoint. A dynamic range under about 30 dB also raises the practical question of whether amplification alone will provide usable audibility.
Sample item from the bank
You are deciding between NAL-NL2 and DSL v5 child for a 3-year-old with a severe sensorineural hearing loss. Which statement about the two prescriptions is accurate?
- DSL v5 child generally prescribes more gain and output than NAL-NL2, especially for severe lossesCorrectDSL aims to make the full speech spectrum audible rather than to maximize predicted intelligibility at a comfortable loudness. It is built on a desired sensation level framework that targets audibility of the long-term speech spectrum within the residual dynamic range, and its pediatric version accounts for a child's need to overhear and to acquire language, whereas NAL-NL2 optimizes predicted speech intelligibility while constraining overall loudness.
- The two prescriptions produce nearly identical targetsIncorrectTargets can differ meaningfully, and the difference tends to grow as the loss becomes more severe, so the choice is not merely a matter of software preference.
- DSL v5 has only a pediatric version, so NAL-NL2 must be used for any adult fittingIncorrectDSL v5 includes both child and adult versions, and the adult version prescribes less gain than the child version.
- NAL-NL2 prescribes more gain than DSL v5 for severe lossesIncorrectNAL-NL2 aims to maximize predicted speech intelligibility while keeping overall loudness no greater than a normal-hearing listener would perceive, whereas DSL v5 child aims to make the speech spectrum audible. As a result, NAL-NL2 typically prescribes less gain than DSL for severe losses, not more.
What to take from it
Whichever prescription you choose, verify to it with real-ear measures. The clinically important step is not which formula you pick but that measured output matches a validated target rather than a manufacturer first fit.
Sample item from the bank
A busy clinic employs an audiology assistant. Which assignment is consistent with accepted supervision requirements for support personnel?
- The assistant performs the diagnostic evaluation independently and reports normal resultsIncorrectDeciding that a result is normal is itself an act of interpretation, so reporting normal results to the patient directly and referring only abnormal results to the audiologist is not acceptable. Obtaining the responses can be delegated. Deciding what they mean cannot.
- The assistant selects and programs hearing aids for straightforward mild losses to reduce the audiologist's schedule burdenIncorrectDevice selection and programming require clinical judgment about candidacy, prescriptive targets and verification, which are within the audiologist's scope.
- The assistant performs technical tasks like nondiagnostic otoscopy and hearing aid checks, while the audiologist interprets and recommendsCorrectAudiology assistants may carry out defined technical tasks under the direction of a supervising audiologist who retains full legal and ethical responsibility, such as nondiagnostic otoscopy, preparing the patient and equipment, checking and cleaning hearing aids, and performing listening checks; interpretation, diagnosis, counseling and treatment planning require the audiologist's clinical judgment and cannot be delegated. State law can narrow these tasks further.
- The assistant works without supervision as long as the audiologist reviews and signs all reports within 30 daysIncorrectRetrospective signature is not supervision; the supervising audiologist must direct the work and remain available according to the applicable state and professional requirements.
What to take from it
Two questions decide any delegation: does the task require clinical judgment, and does state licensure law permit it? The supervising audiologist remains responsible for the outcome no matter who performed the task.
Frequently asked
Why show rationales for the wrong answers instead of just the correct one?
Wrong options on a well-built question are usually built around a specific, common misconception. Understanding why a plausible-looking wrong answer is wrong generalizes to a new question testing the same idea in a way that memorizing a single correct answer does not.
Should study time be split evenly across all five domains?
No. ETS publishes the approximate split: assessment is about 35 percent of the exam and intervention about 25 percent, so those two domains deserve close to 60 percent of practice time, with foundations (about 20 percent), prevention and screening (about 10 percent) and professional responsibilities (about 10 percent) filling out the rest.
Where is the rest of the question bank?
This page shows five worked examples. The full bank, with drills, worksheets, and a weak-area view, is in StudyHub. The Praxis Prep Pass is on the Praxis Prep page, built around the same five domains. The Audiology Praxis study guide is the exam and study-plan page.
Studying for the Praxis? Start with the Audiology Praxis study guide. There is a short free sample on Praxis Prep, and the Praxis Prep Pass is on that page too.
Related
Want more like this? The full question bank lives on Praxis Prep, and every study tool sits inside StudyHub.
Come study with us.