PB max, PI-PB functions and rollover explained
What is PB max, how is a performance-intensity function built, and how is the rollover index calculated and interpreted?
Written by Erica Guberman, Au.D. · Updated November 10, 2026
PB max is the highest word recognition score an ear produces, found by testing at more than one presentation level rather than reading off a single score. Plotting scores across levels builds a performance-intensity function, and comparing PB max to the lowest score at a higher intensity gives the rollover index, a long-taught but imperfect clue toward a retrocochlear site of lesion.
What PB max means
Word recognition lists are built to be phonetically balanced, meaning the phonemes in the list appear in roughly the proportion they occur in everyday English, so PB is shorthand that shows up throughout this corner of speech audiometry. PB max is the highest word recognition score a given ear produces, found by testing at more than one presentation level and taking whichever score turns out to be the best.
A score obtained at a single presentation level is not PB max, even if that single level happens to produce a good result. PB max is a maximum by definition, and a maximum cannot be established by one data point. Confirming a true PB max, and therefore supporting any rollover calculation or site of lesion inference drawn from it, requires sampling performance at more than one intensity.
Building a performance-intensity function
A performance-intensity function for word recognition, often written PI-PB, plots word recognition score against presentation level across a range of intensities. The shape of that function, not any single score on it, is what supports a rollover calculation or a comment on whether performance is degrading at high intensities.
A common default is to test word recognition at a fixed sensation level relative to the SRT, often around 40 dB SL. For a steeply sloping high frequency loss, that fixed level can undershoot the intensity where the ear actually reaches its best score, since much of the high frequency speech energy is still inaudible at a level anchored to low frequency hearing. In that specific configuration, retesting at higher levels, up to somewhere near the uncomfortable loudness level, gives a more trustworthy PB max than accepting the single, fixed-level score.
Calculating the rollover index
The rollover index is calculated as PB max minus PB min, divided by PB max. PB min is specifically the lowest word recognition score obtained at any presentation level above the level where PB max occurred, not the lowest score obtained anywhere on the function. A score from a level below PB max describes the rising part of the function, not rollover, and mixing it into the formula produces a number with no defined meaning.
Put concretely, if the best score on the function is 88 percent at 80 dB HL, and the score at a higher level, 100 dB HL, falls to 44 percent, the rollover index is 88 minus 44, divided by 88, or 0.50. Two scores are the minimum the formula needs: PB max and one lower score at a higher level. With only two levels tested, though, you cannot be sure the first score was the true peak, so the index is less trustworthy. Testing several levels below and above the best score gives a more reliable PB max and rollover index. One tested level cannot support the calculation at all.
Interpreting rollover cautiously
The often-quoted cutoff of 0.45 or higher comes from Jerger and Jerger (1971), who used PAL PB-50 word lists. Other word lists gave other cutoffs: Meyer and Mishler (1985) separated retrocochlear from cochlear ears at a rollover index above 0.35 using Auditec NU-6 recordings. Listeners with normal hearing or cochlear loss can also show some decline above PB max, usually mild to moderate. The direction of the teaching, that a steep decline in word recognition at high intensities leans retrocochlear, is a genuinely useful clinical signal.
Any single cutoff is a convention tied to the word list and recording it was derived from, not a precisely established diagnostic line. A large rollover index should prompt further retrocochlear workup, such as auditory brainstem response testing or imaging, rather than stand alone as a definitive answer about site of lesion.
Try a question from the bank
Same format as the exam: options with a reason given for every one of them, from the real Ears with Erica question bank. More like it live in StudyHub.
Sample item from the bank
Word recognition is 76 percent at one level, 40 dB SL re SRT. The report calls this PB max. Why is that not necessarily accurate?
- PB max requires the highest score across multiple levels, so one level cannot show itCorrectPB max is a maximum by definition, which requires sampling performance at more than one intensity level to confirm that no higher score would be obtained at a different level. A single-level score, even a reasonably good one, is simply a word recognition score at that level, not a confirmed PB max, and cannot support rollover or site-of-lesion calculations that specifically require a true PB max.
- PB max can only be measured with spondee words, not monosyllabic wordsIncorrectPB max is specifically a word recognition (monosyllabic word) concept; spondee words are used for the SRT, not for the performance-intensity function that PB max comes from, so this objection misidentifies the actual issue with the scenario.
- 76 percent is too low a score to ever be considered a PB max under any circumstancesIncorrectPB max simply refers to the highest score obtained across levels for that particular ear, whatever that value turns out to be; a lower overall score in an ear with significant hearing loss can still be a legitimate PB max if it is indeed the best score obtained across multiple tested levels.
- There is no issue; a single-level word recognition score is equivalent to PB maxIncorrectThis is the core error the scenario is testing: PB max specifically requires testing at multiple levels to identify the true maximum, so a single-level score cannot be assumed equivalent to PB max without that additional testing.
What to take from it
Before a word recognition score is called PB max, or used to calculate a rollover index, confirm that testing was actually performed at more than one intensity level; a single-level score is not the same claim as a demonstrated maximum.
Sample item from the bank
Performance-intensity function: PB max 88% at 60 dB HL, falling to 60% at 90 dB HL (above where PB max occurred). Using the standard rollover index, what is the calculated value?
- Approximately 0.32, calculated as PB max minus PB min divided by PB maxCorrectThe rollover index formula is (PB max minus PB min) divided by PB max, where PB min is the lowest score obtained at any level above where PB max occurred. Here, (88 minus 60) divided by 88 equals 28 divided by 88, which is about 0.32.
- Approximately 0.68, calculated as PB min divided by PB maxIncorrectThis calculates the ratio of PB min to PB max directly, rather than applying the actual rollover index formula, which uses the DIFFERENCE between PB max and PB min divided by PB max, not the ratio of the two scores to each other.
- Approximately 28, calculated as PB max minus PB min without dividing by PB maxIncorrectThis gives only the raw percentage-point difference between the two scores (28 points) but omits the final step of dividing by PB max, which is required to produce the dimensionless rollover index.
- The rollover index cannot be calculated from this informationIncorrectThe stem gives both values the formula needs. PB min is defined as the lowest score obtained at any level ABOVE where PB max occurred, and the stem places the lower score at 90 dB HL, above the 60 dB HL PB max level; a higher-intensity level producing a lower score than PB max is exactly the pattern the rollover formula is designed to quantify, so the calculation can proceed as given.
What to take from it
Keep the rollover formula's two ingredients straight: PB max is the best score anywhere on the function, and PB min is specifically the worst score at any level ABOVE where PB max occurred, not simply the lowest score obtained anywhere on the function.
Frequently asked
Is a word recognition score from one presentation level ever called PB max?
It should not be. PB max is a maximum by definition, which requires comparing scores across more than one intensity to confirm that no higher score exists elsewhere on the function. A single-level score, even a good one, is just a word recognition score at that level.
What if the performance-intensity function only has one or two tested points?
With one point, no. With two points, the arithmetic works if the higher-level score is lower, but you cannot be sure the first score was the true peak, so treat the index as tentative. A function with several levels below and above the best score gives a more trustworthy PB max and rollover index.
Does a high rollover index confirm a retrocochlear lesion by itself?
No. Treat it as a suggestive signal rather than a definitive one. The direction, large rollover leaning retrocochlear, is solid teaching, but the specific numeric cutoff commonly cited is a convention to apply cautiously, and a single number should prompt further workup rather than settle the diagnosis on its own.
Want to practice this? StudyHub has over 1,300 questions with a rationale for every option.
Related
Want more like this? The full question bank lives on Praxis Prep, and every study tool sits inside StudyHub.
Come study with us.
Join a live Kahoot session, or pick a plan and get into StudyHub today.